High Accuracy Conductivity & Temperature Sensor
about this product:
X2change™ is the industry’s leading family of field-swappable sensor heads. Each sensor head contains its own embedded calibration and can be moved from instrument to instrument without impacting accuracy. Changing sensors is easy: simply unscrew one sensor head and replace it with another.
Key Benefits:
Zero Down Time – With X2•Series sensors, recalibrated sensors are sent to the instrument instead of sending the instrument to the recalibration centre.
Reduced Logistical Costs – With X2•Series, small sensor heads are shipped instead of heavy instruments.
Increased Flexibility – Field-swappable sensor heads enable any organization – big or small – to become a virtual recalibration centre by stocking spare calibrated sensor heads.
One Instrument, Multiple Applications – Change the sensor type on any instrument to suit specific application requirements. This means instrument duplicates (identical instruments dedicated to different pressure ranges, e.g., separate instruments for Turbidity, pH, Chlorophyll, etc.) become a thing of the past.
Improved Absolute Pressure Accuracy – Choose the best full-scale pressure range to suit your deployment depth.
X2change™ sensor heads are used exclusively with X2•Series / Orange Line instrumentation. Total flexibility of instrument model, sensor type, and sensor range ensures that the right instrument is always available. Please refer to the X2•Series brochure for a list of instruments, applications, and specifications.
Collect the most accurate, highest quality data possible by using X2change™ High Accuracy Conductivity-Temperature sensors. Sensors calibrated to high accuracy are measured against a laboratory standard, ensuring precise data collection. High accuracy sensors are ideal for places with minimal changes in the environment, or in deep water where the full scale is larger; therefore high accuracy and precision is more significant. Conductivity-Temperature (CT) sensors are used for characterizing the water column. All X2change™ High Accuracy CT sensors have a range of 0-90 mS/cm and -5 to 45 °C, accuracy of ±0.003 mS/cm and 0.002 to 0.005 °C, resolution of 0.001 mS/cm and 0.001 °C and a response time of 25 ms (conductivity) and 100 ms (temperature). Please contact the AML Sales team if you are unsure which option is best for your project.
Product Documents
Max Depth | 6000 m |
Range | C: 0-90 mS/cmT:-5-45 °C |
Precision (±) | C: 0.003 mS/cmT: 0.003 °C |
Accuracy (±) | C: 0.003 mS/cmT: 0.002 °C |
Resolution | C: 0.001 mS/cmT: 0.001 °C |
Response Time | C: 25 msT: 100 ms |
Notes | Combined Conductivity & Temperature |